Alcatel-Lucent ap70 ユーザーズマニュアル

ページ / 60
OmniAccess OAW-AP70: Installation Guide
32
Part 031644-00
May 2005
The maximum length for FE cables is 100 meters (325 feet). 
When the OmniAccess OAW-AP70 is installed in an air-handling space, as 
described in NEC (2002) Article 300.22 (C), POE is required. Also, any FE cable 
installed in such spaces should be suitable under NEC Article 800.50 and 
marked accordingly for use in plenums and air-handling spaces with regard to 
smoke propagation, such as CL2-P, CL3-P, MPP or CMP.
Install cables in accordance with all applicable local regulations and practices.
Serial Breakout Adapter
The optional serial breakout adapter is used to separate the serial 
communications lines from the OmniAccess OAW-AP70 FE+SPOE port. This 
allows the administrator to connect a local serial console directly to the AP and 
access the 
apboot prompt for manual provisioning.
The serial breakout adapter pin-outs are shown in 
F
IGURE
A-2 Alcatel Serial Breakout Adapter
RJ-45 Male "To Network" Pin-Out
1
2
3
4
5
6
7
8
ETH Tx+ (POE 
negative)
ETH Tx– (POE 
negative)
ETH Rx+ (POE 
positive)
ETH Rx– (POE 
positive)
Serial TxD
Serial TGND
Serial RxD
Serial RGND
RJ-45 Male "To AP" Pin-Out
1
2
3
4
5
6
7
8
ETH Rx+ (POE 
negative)
ETH Rx– (POE 
negative)
ETH Tx+ (POE 
positive)
ETH Tx– (POE 
positive)
RxD
TxD
SG
5
4
3
2
1
9
8
7
6
DB-9 Female Pin-Out
Input
Output
Direction
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Internal Adapter Wiring
"To AP"
"To Network"
To Console