Using the DXP-HT Project Wizard
34
DXP-HT v1.3 - Programmer’s Guide
Govern Power - This option enables governing power to the device, which means that
the System constantly monitors power to the device (for use with power sensors) rather
than simply toggling power On/Off.
Device/Power Feedback - This option enables the display of power status of the device
on the touch panel. If this option is enabled, use the radio buttons to specify a Power
Sensing Method, based on the type of power sensor being used with the device (PSS2,
VSS2 or TVS).
Power Sensing Method - Activated by enabling the Govern Power option (described
above). Use the radio button to select the method of power sensing being used. This
available power sensors include: PCS2 (Dual Power Current Sensor), VSS2 (Video Sync
Sensor), and TVS (TV Sensor).
IR Timing Parameters - Use the up/down arrows to adjust the time gap between Power
On and Power Off IR pulses, in 1/10 second increments (default = 50).
Working with MAX Servers
DXP-HT v1.3 (or higher) supports MAX-MMS and MAX-IMS media servers. DXP-HT treats
these devices essentially the same as any other IP-controlled device (such as MP3 players). There
are just a few points to understand in order to add MAX servers to a DXP-HT project:
The MAX-MMS and MAX-IMS servers are IP-control only, and they must be used with
AMX G4 touch panels (see Supported Touch Panels).
Each MAX-AVM A/V Module connected to a MAX-MMS server must each be set to a
unique zone number (per server).
If multiple MAX-MMS or MAX-IMS servers are used in a project, each server must have
its own unique IP Address.
Refer to the MAX-MMS and MAX-IMS Installation Guides (available online at www.amx.com)
for details.
Each device IP Address must be unique, with only one exception: MAX servers can
use one IP with multiple output zones per display name entry. For example, a MAX-
IMS assigned to IP Address 1.1.1.1 - Zone 1 can exist in the same project as another
MAX-IMS assigned to IP Address 1.1.1.1 - Zone 2. But you cannot assign two MAX
servers with the same IP Address and Output Zone (you will receive an error
message).
use one IP with multiple output zones per display name entry. For example, a MAX-
IMS assigned to IP Address 1.1.1.1 - Zone 1 can exist in the same project as another
MAX-IMS assigned to IP Address 1.1.1.1 - Zone 2. But you cannot assign two MAX
servers with the same IP Address and Output Zone (you will receive an error
message).