Stack Pulse Parameters - If the Tune Using XCH Command option is de-selected, the 
Stack Pulse Parameters options become available. The Stack Pulse option mimics the 
XCH commands, but uses IR pulses instead of sending commands.
 
Click the up/down arrows to adjust the number of digits to use when tuning the 
device (or the total number of channel digits - whichever is larger). The default 
setting is 3 digits.
 
Enable the Send Enter option to always send an Enter command with each stacked 
pulse.
 
IR Carrier - Some devices (i.e. Sony Control-S devices) use a wired IR signal, instead of 
using an IR emitter. In some cases, the signal is the same as is transmitted by the IR 
emitter, but it does not transmit a carrier signal. This check box will turn on or off the 
carrier signal. The default setting is On.
 
Wired IR - Enable this option if the wired IR device requires Mode Serial signals.
Device Configuration dialog - Power Control tab
The options in the Power Control tab (FIG. 5) allow you to configure power control for the AV 
equipment. This tab requires that you know how your equipment operates.
 
Device Supports Discrete On/Off - If you have mapped Discrete On/Off functions for 
this device, you can select to enable support of Discrete On/Off. 
• Mode 4
Mode 4 should only be used for channels 0-199, and sends the same IR sequences 
as the CH command.
FIG. 5  Device Configuration dialog - Power Control tab