avolites pearl exper ttitan ユーザーズマニュアル

ページ / 169
Copyright Avolites Limited 2010
8. Cue Lists  - Page 97
 
 
 
 
PearlExpertTitan_Man_v3.doc  29/03/2010 13:28:00 
• 
[Link After Previous Cue]: The cue fires when the previous cue 
has finished its delay in and fade in times. A Link Offset can be 
set to add a delay between the previous cue finishing and this 
cue firing. The offset can be given as a time in seconds, or as a 
percentage of the fade time of the previous cue. 
• 
[Link With Previous Cue]: The cue fires at the same time as the 
previous cue fires. A Link Offset can be set to add a delay 
between the previous cue firing and this cue firing, set either in 
seconds or as a percentage of the fade time of the previous 
cue. 
 
These options allow you to create complex self timed sequences by 
building up simple steps. For example if you wanted the following 
effect: 
• 
Go is pressed, Fixture one starts fading up over 20s 
• 
After 10s Fixture two fades up over 15s 
• 
Both lights stay on for 5s 
• 
Both lights go off in 3s 
You could program 
• 
Cue 1 - Fixture 1 @ 100%, Fade In 20s, Link Wait For Go 
• 
Cue 2 - Fixture 2 @ 100%, Fade In 15s, Link With Previous, 
Link Offset 10s 
• 
Cue 3 - Fixture 1 AND 2 @ 0%, Fade Out 3s, Link After 
Previous, Link Offset 5s 
Note:  To obtain the effect which was called “cue overlap” in previous 
versions of software, use [Link With Previous Cue] and set a 
percentage Link Offset time. Link Offset of 100% is equivalent 
to Cue Overlap of 0% and vice versa.