HP 20-700 ユーザーズマニュアル

ページ / 219
Chapter 3
Entering Configuration Data 71
Chapter 3
Note
The following procedures assume that you will make all entries 
during one operator panel entry session. Each item is saved as it 
is changed, except for the library’s SCSI ID: to save a revised 
library SCSI ID, you must reset the library by pressing the 
[RESET] button.
Setting the Library’s SCSI ID
Setting the Library’s SCSI ID
Setting the Library’s SCSI ID
Setting the Library’s SCSI ID
If the control path for the library is SCSI, you must enter the library’s SCSI ID at 
the operator panel. Set the library SCSI ID from the Lib SCSI I/F Config menu.
Note
The information below explains special circumstances for 
selecting a SCSI ID (address) for the library:
When configuring the library to a Unix-based workstation, HP 
recommends that you use a dedicated SCSI client host bus adapter (HBA):
— For wide SCSI adapters, you may assign any address from 0 to 14 for 
the library.
— For narrow SCSI adapters, the range of addresses is 0 to 6.
If you choose to use the embedded system bus on the SPARC station, select 
address 6, 5, 2, or 0 for the library; the remaining targets are reserved for 
Sun peripherals.
For RISC System/6000 machines, available addresses on the embedded 
system bus are 6, 5, 3, and 2.
To set the library’s SCSI ID:
1.  From the online status screen, press the [MENU] button. 
The Main Menu will display.
2.  Press the down arrow button until the cursor underscores 
CONFIGURATION.
3. Press 
the 
[SELECT] button.
The main Configuration Menu will appear and the cursor will line up with 
LIBRARY CONFIG.