Removal and replacement procedures 70
7.
Remove the battery.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.
System maintenance switch
Position
Default
Function
S1
Off
Off = iLO 2 security is enabled.
On = iLO 2 security is disabled.
S2
Off
Off = System configuration can be modified.
On = System configuration is locked and cannot be modified.
On = System configuration is locked and cannot be modified.
S3
Off
Reserved
S4
Off
Reserved
S5
Off
Off = Power-on password is enabled.
On = Power-on password is disabled.
S6
Off
Off = Normal
On = ROM treats system configuration as invalid.
S7
Off
Reserved
S8
Off
Reserved
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all
system configuration settings from both CMOS and NVRAM.
CAUTION:
Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
properly configure the server or data loss could occur.