Parameter ID 
45 
Parameter 
Name 
Loop Gain Fine Adjustment 
Data 
Loop Gain Fine Adjustment (Unit: Multiple × 1000) 
Return Value  0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter makes fine adjustments to the servo's loop gain (inertia of the motor 
and mirror, and the torque constant of the motor are related). 
Note: This is usually set appropriately at shipping. 
Related 
Command 
/Parameter 
 
 
 
Parameter ID 
48 
Parameter 
Name 
VR head1 AB offset 
Data 
A/B-phase offset of encoder VR adjustment head 1 (Unit: none) 
Return Value  0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to adjust the offset of encoder signal. 
Note: This is usually set appropriately at shipping. 
Related 
Command 
/Parameter 
 
 
Parameter ID 
49 
Parameter 
Name 
VR head1 A gain 
Data 
A-phase amplitude of encoder VR adjustment head 1 (Unit: none) 
Return Value  0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to adjust the A-phase amplitude of the encoder signal. 
Note: This is usually set appropriately at shipping. 
Related 
Command 
/Parameter 
 
 
Parameter ID 
50 
Parameter 
Name 
VR head1 B gain 
Data 
B-phase amplitude of encoder VR adjustment head 1 (Unit: none) 
Return Value  0: Parameter setting successful 
1: Parameter setting unsuccessful 
Explanation 
This parameter is used to adjust the B-phase amplitude of the encoder signal. 
Note: This is usually set appropriately at shipping. 
Related 
Command 
/Parameter