Canon GM-1000 ユーザーズマニュアル
![Canon](https://files.manualsbrain.com/attachments/4b6818c07b947b910f8cfb49338c2c63bdefaee1/common/fit/150/50/61ea34cb812b6780fe3b16f0b9221bd2f7635c65cee2473b66396d8b72cd/brand_logo.png)
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
Users Manual 1.20
123
Parameter ID
51
Parameter
Name
VR head2 AB offset
Data
A/B-phase offset of encoder VR adjustment head 2 (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to adjust the offset of the encoder signal.
Note: This is usually set appropriately at shipping.
Related
Command
/Parameter
Command
/Parameter
Parameter ID
52
Parameter
Name
VR head2 A gain
Data
A-phase amplitude of encoder VR adjustment head 2 (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to adjust the A-phase amplitude of the encoder signal.
Note: This is usually set appropriately at shipping.
Related
Command
/Parameter
Command
/Parameter
Parameter ID
53
Parameter
Name
VR head2 B gain
Data
B-phase amplitude of encoder VR adjustment head 2 (Unit: none)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation
This parameter is used to adjust the B-phase amplitude of the encoder signal.
Note: This is usually set appropriately at shipping.
Related
Command
/Parameter
Command
/Parameter