Canon GM-1000 ユーザーズマニュアル

ページ / 140
 
CANON  Digital Galvano Scanner System  GM-1000 Series 
Users Manual 1.20
 
 
 
  
131 
Priority: Low 
Error 
Hex 
Monitor Item 
Error Condition 
Setting 
Change 
Possible 
/Impossible 
(Parameter) 
System 
status after 
error 
Digital 
Output 
Recovery Method 
Clock lack 
0x0008
High-speed serial communications 
clock 
The clock is no longer input 
Impossible 
 
 
Input the clock 
normally. If input 
normally it will return. 
Format error 
0x0040
Command format 
An undefined command or parameter is 
sent. 
Impossible 
Error output 
only 
(Axis1) 
Connector 
B1 
 
Monitor 
Board 
D2 
 
 
(Axis 2) 
Connector 
A3 
 
Monitor 
Board 
D5 
 
Error clearance 
(C01) 
Command data error 
0x0080
Command data 
Command data is illegal. 
No data is given to a command requiring 
data. 
Data is given to a command requiring no 
data. 
Data outside the setting range is set. 
Impossible 
Parameter error 
0x0100
Parameter value 
A parameter value is beyond the setting 
range. 
Impossible 
Status error 
0x0200
Command description 
A command not valid for the current status 
is sent. 
Impossible 
Communication error 
0x0400
Communication flag 
Communication flag time-out occurs. 
Impossible 
Out-position error 
0x2000
Encoder pulse count 
The setting of P24 (Out-position Width) is 
exceeded. 
Possible 
(P24)