5.2. Analog Monitor Output Selecting 
The analog monitor output can be switched to monitor various operation and signal statuses. 
This switching can be executed from [Control Software] or [RS-232C command send]
 
Output contents 
Terminal 
Monitor Board 
Signal Name 
Power-on 
Selection
Signal Description 
Signal Level (At 
Power-on) 
2 (Axis 1) 
6 (Axis 2) 
A2 (Axis 1) 
A6 (Axis 2) 
 
Phase A of Encoder Head 1 
 
 
Phase A of Encoder Head 2 
 
 
Phase A of encoder after synthesis 
 
Positional deviation signal 
1.5 mV / pulse 
3 (Axis 1) 
7 (Axis 2) 
A3 (Axis 1) 
A7 (Axis 2) 
 
Position 
0.091 mV / pulse 
Velocity 
0.091    mV / pulse / 10 
 Coarse 
angle 
 
 Fine 
angle 
 
4 (Axis 1) 
8 (Axis 2) 
A4 (Axis 1) 
A8 (Axis 2) 
 
Phase B of Encoder Head 1 
 
 
Phase B of Encoder Head 2 
 
 
Phase B of encoder after synthesis 
 
Target position 
0.091 mV / pulse 
 
The signal level differs between signals. The output magnification can be switched individually.