Juniper CBL-M40-PWR-AU ユーザーズマニュアル

ページ / 268
Maintain and Replace Cooling System Components
Maintain and Replace the Fan Tray
155
Install the Air Filter
To install the air filter, follow this procedure (see Figure 68):
1.
Attach an ESD wrist strap to your bare wrist, and connect the wrist strap to one of the 
two ESD points on the chassis.
2.
Grasp the sides of the air filter and push it firmly over the air intake, inserting its metal 
prongs into the chassis.
Figure 68:  Install the Air Filter
Maintain and Replace the Fan Tray
The fan tray is located at the rear of the chassis, beneath the upper impeller assembly (see 
Figure 2). To check the status of the fans in the fan tray, issue the 
show chassis environment
 
command. The output refers to the individual fans in the fan tray as the 
Rear Left Fan
Rear Center Fan
, and 
Rear Right Fan
:
user@host> show chassis environment
Class Item                   Status     Measurement
. . .
Fans  Top Impeller           OK         Spinning at normal speed
      Bottom Impeller        OK         Spinning at normal speed
      Rear Left Fan          OK         Spinning at normal speed
      Rear Center Fan        OK         Spinning at normal speed
      Rear Right Fan         OK         Spinning at normal speed
. . .
For further description of the output from the command, see the JUNOS Internet Software 
Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management
.
To replace the fan tray, perform the following procedures:
1064