Maintain and Replace Cooling System Components
Maintain the Impeller Assemblies
157
Figure 70:  Install the Fan Tray
Maintain the Impeller Assemblies
 
The router has two non-interchangeable impeller assemblies. The lower impeller is located 
behind the craft interface at the front the chassis (see Figure 1), and the upper assembly is 
located above the fan tray at the rear of the chassis (see Figure 2). They work together to cool 
the Packet Forwarding Engine components. 
During normal operation, the impellers run at less than full speed. The following conditions 
automatically cause the impellers to run at full speed and trigger the indicated alarm:
„ One of the impellers fails (red alarm).
„ One of the impellers is removed (yellow alarm). For removal instructions, see the 
following sections:
„
„
„ The router temperature exceeds the “temperature warm” threshold (yellow alarm).
„ The temperature of the router exceeds the maximum (“temperature hot”) threshold (red 
alarm and automatic shutdown of the power supplies). 
For more information about impeller-related alarms, see “Hardware and Interface Alarm 
Messages” on page 192. 
To check the status of the impeller assemblies, issue the 
show chassis environment
 command. 
The output refers to the 
Top
 and 
Bottom
 impellers, as shown in this example:
user@host> show chassis environment
Class Item 
Status
Measurement
...
Fans  Top Impeller           OK         Spinning at normal speed
      Bottom impeller        OK         Spinning at normal speed
...
For further description of the output from the command, see the JUNOS Internet Software 
Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management
.
1053