Juniper CBL-M40-PWR-AU ユーザーズマニュアル

ページ / 268
Hardware Component Overview
Cooling System
23
Cooling System
The cooling system consists of separate subsystems (sets of fans and impellers) that draw 
room air into the chassis to keep its internal temperature below a maximum acceptable level. 
When the temperature is below the maximum, the fans and impellers function at less than 
full speed. If sensors detect that the temperature of a component has exceeded the 
acceptable maximum—for example, because an impeller is removed—the speed of the 
remaining impellers and fans is automatically increased to reduce the temperature. The fans 
and impellers can function at the higher speed indefinitely.
For more information about the cooling system, see the following sections:
Cooling System Components
The cooling system has the following components. Except as noted, they are hot-removable 
and hot-insertable, as described in “Field-Replaceable Units (FRUs)” on page 4.
„ Air intake vent and air filter—Provide an opening for room air to enter the router. They 
are located at the bottom of the chassis front, below the craft interface, as shown in 
Figure 1. The air filter prevents dust and other particles from entering the cooling 
system. For replacement instructions, see “Maintain and Replace the Air Filter” on 
page 154.
„ Upper and lower impeller assemblies—Cool the Packet Forwarding Engine components 
(backplane, SCB, FPCs, and PICs). The lower impeller assembly is located behind the 
craft interface at the front the chassis, and the upper assembly is located above the fan 
tray at the rear of the chassis. Each assembly houses two impellers for redundancy. The 
assemblies are not interchangeable. For replacement instructions, see “Replace the 
Lower Impeller Assembly” on page 158 
and “Replace the Upper Impeller Assembly” on 
page 159.
„ Fan tray—Cools the Routing Engine and backplane. The tray houses three fans for 
redundancy and is located above the Routing Engine at the upper rear of the chassis (see 
Figure 2). For replacement instructions, see “Maintain and Replace the Fan Tray” on 
page 155.
„ Power supply integrated fan—Cools the power supply. It is not field-replaceable.
Do not remove the air filter for more than a minute or so 
while the router is operating. The fans and impellers are 
powerful enough to draw in foreign material, such as bits 
of wire, through the unfiltered air intake, which could 
damage router components.