Solenoid Hold-in Test
specified in the previous
SOLENOID PULL-IN TEST
,
discon-
nect solenoid “C” terminal/battery negative test lead at
battery negative end only; reconnect loose end of this
test lead to battery positive, instead.
battery negative end only; reconnect loose end of this
test lead to battery positive, instead.
If pinion remains in
pull-in position, solenoid is working properly. If pinion does
not remain in pull-in position, solenoid should be replaced.
not remain in pull-in position, solenoid should be replaced.
Solenoid Return Test
specified at the end of the previous
disconnect solenoid “50” terminal/battery positive
test lead at either end.
If pinion returns to its original posi-
tion, the solenoid is working properly. If pinion does not return
to its original position, solenoid should be replaced.
to its original position, solenoid should be replaced.
DISASSEMBLY, INSPECTION
AND REPAIR
AND REPAIR
1.
Remove field wire (22).
2.
Remove thru-bolts.
3.
Remove two end cover screws, O-rings,
and end cover.
Figure 5-10. Hold-In Test
Figure 5-11. Return Test
Battery
b0162x5x
“C” terminal
“50” terminal
Battery
b0163x5x
“C” terminal
“50” terminal
Figure 5-12. Removing the Thru-Bolts
Figure 5-13. Removing End Cover
4860
Thru-bolts
3548a
End cover
End cover
screws (2)
screws (2)
5