Extron electronic DSC 3G-HD A ユーザーズマニュアル

ページ / 4
1
DSC 3G-HD A Scaler • Setup Guide
The Extron DSC 3G-HD A is a 3G-SDI to HDMI scaler that converts 3G-SDI, HD-SDI, and SD-SDI signals to HDMI. It accepts 
and scales SMPTE video resolutions from 480i and 576i up to 1080p @ 60 Hz and 2K, and offers multiple output rates up to 
1920x1200, including HDTV 1080p/60 and 2k. Stereo audio embedding and an SDI input loop-through are also provided. 
This setup guide provides step-by-step instructions for an experienced user to set up and configure a DSC 3G-HD A. It covers 
how to perform basic operations using the front panel controls and selected Simple Instruction Set (SIS
) commands.
NOTE:
  For full installation, configuration, menus, connector wiring, and operation details, see the DSC 3G-HD A and 
DSC HD-3G A User Guide, available at 
.
Installation 
Rear Panel Features
HDMI
3G/HD/SD-SDI
LOOP THRU
100-240V ~ 0.3A MAX
50-60 Hz
DSC 3G-HD A
REMOTE
OUTPUT
AUDIO
INPUT
L
R
2
3
1
5
4
RS-232
Tx Rx G
6
Mounting and Cabling the DSC 3G-HD A
1. 
Disconnect power: Turn off or disconnect all equipment power sources.
2. 
Mount the unit: (Optional) Mount the DSC 3G-HD A either in a rack using 
shelf mounting brackets (RSU 129 or RSB 129) or under furniture using 
furniture mounting brackets (MBU 125) (see figures 1 and 2 at right). A false 
face plate (RFF 052) can be fitted on top of the low profile DSC if desired.
3. 
Connect the input: Connect an SDI video source to the 3G/HD/SD-SDI 
BNC input connector 
b
4. 
Connect a monitor: (Optional) Connect a local monitor to the buffered 
Loop Thru SDI connector 
c
5. 
Connect analog audio input: (Optional) Connect analog audio from the 
source to the captive screw Audio input connector 
d
NOTE:
  To embed analog audio from this input, you must first set 
 (see page 4).
6. 
Connect the output: Connect an HDMI display device to the HDMI  
output connector 
e
 for HDMI output (with optional analog audio if 
connected and embedded).  
7. 
Connect a control device: For remote control via SIS commands or 
the PCS Windows
®
-based control software:
 
z
RS-232 — For serial RS-232 control, connect a host computer or 
control system to the 3-pole captive screw RS-232 connector 
f
.  
RS-232 protocol (default values) are 9600 baud, 1 stop bit, no 
parity, 8 data bits, no flow control. 
 
z
USB — Connect a host computer or control system to the front 
panel mini USB port (
b
 in the front panel illustration on page 2) 
for configuration and control via Extron PCS Control software.
8. 
AC power connector — Connect the supplied US standard IEC 
power cord between this connector 
a
 and a 110-220 V 50-60 Hz AC 
power source.
Figure 2. 
  Under-furniture Mounting
 DVC 501 SD
DIG
ITAL
 VID
EO CONV
ERT
ER
(2) 4-40 x 3/16" screws
Use 2 mounting holes on
opposite corners.
Half-rack
false front panel
uses 2 front holes.
a
  AC power connector
b
  3G/HD/SD-SDI video connector
c
  Buffered loop-through connector
d
  5-pole captive screw audio input  
 connector
e
  HDMI output connector 
f
  3-pole RS-232 captive screw  
 connector
Figure 1. 
  Rack Mounting
MBU 125 Mounting Bracket
#8 Screw
(4) Places
Each Side
Mounting 
Screws
(2) Places
Each Side