Installation
26
F232058
Electrical Installation
The AC inverter drive requires a clean power 
supply free from voltage spikes and surges. 
A voltage monitor should be used to check 
incoming power. The customer’s local power 
company may provide such a monitor.
If input voltage measures above 230V for a 
200V drive or above 440V for a 400V drive, 
ask the power company to lower the voltage. 
As an alternative, a step-down transformer kit 
is available from the distributor. Voltages 
above 250V and 490V require additional 
measures. Contact the distributor or the 
manufacturer for assistance.
This machine must be installed, adjusted, 
and serviced by qualified electrical 
maintenance personnel familiar with the 
construction and operation of this type of 
machinery. They must also be familiar with 
the potential hazards involved. Failure to 
observe this warning may result in personal 
injury and/or equipment damage, and may 
void the warranty.
SW004
WARNING
Dangerous voltages are present in the 
electrical control box(es) and at the motor 
terminals. Only qualified personnel familiar 
with electrical test procedures, test 
equipment, and safety precautions should 
attempt adjustments and troubleshooting. 
Disconnect power from the machine before 
removing the control box cover, and before 
attempting any service procedures.
SW005
WARNING
Ensure that a ground wire from a proven 
earth ground is connected to the ground lug 
near the input power block on this machine. 
Without proper grounding, personal injury 
from electric shock could occur and machine 
malfunctions may be evident. 
SW008
WARNING
Never touch terminals or components of 
the AC inverter drive unless power is 
disconnected and the “CHARGE” indicator 
LED is off. The AC inverter drive retains 
potentially deadly voltage for some time 
after the power is disconnected. There are 
no user-serviceable parts inside the 
AC inverter drive. Tampering with the drive 
will void the warranty.
SW009
WARNING
When controlling the AC inverter drive with 
a parameter unit, the machine’s computer 
and its safety features are bypassed. This 
would allow the basket to rotate at high 
speeds with the door open. When using a 
parameter unit to control the AC inverter 
drive, a large sign should be placed on the 
front of the machine warning people of the 
imminent danger.
SW003
DANGER