28
F232058
Electrical Installation (
Continued)
Electrical Specifications
Voltage Designation
Standard
Electric Heat
Model
Code
Vo
lt
a
g
e
Cyc
le
P
h
ase
Wire
Full Load
Amps
Bre
ake
r
AW
G
mm
2
Full Load
Amps
Bre
ake
r
AW
G
mm
2
35
M
550-575
50-60
3
3
4
15
14
3x2.5
Not available in this voltage.
M*
550-575
50-60
3
3
6
10
14
3x2.5
Not available in this voltage.
N
440-480
50-60
3
3
4
15
14
3x2.5
32
35
8
3x10
N*
440-480
50-60
3
3
6
15
12
3x4
25
30
10
3x6
P
380-415
50-60
3
3
4
15
14
3x2.5
32
35
8
3x10
P*
380-415
50-60
3
3
6
15
12
3x4
22
30
10
3x6
Q
200-240
50-60
3
3
10
15
14
3x2.5
50
50
8
3x10
Q*
200-240
50-60
3
3
10
20
12
3x4
38
50
6
3x16
T
200-240
50-60
1
2
13
15
14
2x2.5
Not available in this voltage.
T*
200-240
50-60
1
2
19
30
10
3x6
Not available in this voltage.
50
M
550-575
50-60
3
3
6
15
14
3x2.5
Not available in this voltage.
M*
550-575
50-60
3
3
10
15
14
3x2.5
Not available in this voltage.
N
440-480
50-60
3
3
4
15
14
3x2.5
43
50
8
3x10
N*
440-480
50-60
3
3
11
20
12
3x4
38
50
6
3x16
P
380-415
50-60
3
3
4
15
14
3x2.5
43
50
8
3x10
P*
380-415
50-60
3
3
11
20
12
3x4
33
40
8
3x10
Q
200-240
50-60
3
3
10
15
14
3x2.5
76
80
4
3x25
Q*
200-240
50-60
3
3
19
30
10
3x6
56
70
4
3x25
T
200-240
50-60
1
2
18
25
10
2x6
Not available in this voltage.
T**
200-240
50-60
1
2
26
50
6
2x16
Not available in this voltage.
85
M**
550-575
60
3
3
13
25
10
3x4
Not available in this voltage.
N**
440-480
50-60
3
3
13
25
10
3x4
55
60
6
3x16
P**
380-415
50-60
3
3
13
25
10
3x4
55
60
6
3x16
Q**
200-240
50-60
3
3
24
40
8
3x6
105
110
2
3x35
Note: 
Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.