2 • Hardware installation
3. Review SCSI pin-out (see 
on page 27) and punch-block pin-out and cut wires to the required 
length to reach their respective ports on the punch-down block.
4. Use punch-down tool to press wires down into block terminals.
5. Use cable ties to secure the wires and SCSI cable to the punch-down block (see 
Note
Cable ties should not allow movement of wires or SCSI cable.
6. Connect the 68-pin SCSI connector of the WAN cable  to the connector on the rear panel of the 
Model 2616RC.
68-pin SCSI to open end, 6 foot cable (part #10-3096TM68-6)—Obsolete 
1. This 6-foot WAN cable (see 
) connects the 2616RC T1/E1 lines to a punch-down block via 28 
gauge wire (0.3mm). Check your punch-down block wire gauge requirements as most punch-down blocks 
will not hold 28-gauge wire securely in place. 
Figure 15. SCSI-to-open-end 6-foot WAN cable (obsolete)
2. See appendix B,
on page 78 for pin-
out information.
68-pin SCSI to 64-pin female Telco (part #10-3096TM68/64-6)
Do the following to install the 6-foot cable adapter for connection of the 2616RC to a Patton E1 balun rack 
Models 464RC and 466RC. 
1. Connect the 68-pin SCSI connector of the WAN cable  to the connector on the rear panel of the 
Model 2616RC.