Maintenance
69
Model 2616RC T-DAC User Manual 
5 • Troubleshooting and maintenance
– To save the displayed data as a text file, use your browser’s Save function (see 
). Using Netscape 
or Internet Explorer, for example.
• Click  the  File menu.
• Click Save As. A dialog box will appear. Use the dialog to save the data displayed on your browser 
(your T-DAC configuration parameters) to a text file. 
• Select the folder in which you want to store the file, 
• Type  a  file  name.
• Click Save.
Figure 58. Saving the access server flash memory configuration data as a text file
Removing the defective Model 2616RC
1. Remove the replacement Model 2616RC from its shipping container and place it near the chassis in which 
the malfunctioning Model 2616RC is located.
Note
The Model 2616RC T-DAC blades are hot-swappable, so it is not 
necessary to deactivate the rack chassis before replacing a blade.
2. Disconnect and label the following cables from the malfunctioning Model 2616RC:
– The T1/E1 WAN cable (68-pin SCSI connector)
– The T1/E1 modem cable (RJ-21X connector)
– The RS-232 CONFIG cable
– The 10/100 Ethernet cable