Maytag mde-mdg21pra ユーザーズマニュアル

ページ / 66
38
16022904 Rev. 0
©2004 Maytag Appliances Company
WARNING
!
To avoid risk of electrical shock, personal injury or death;
disconnect power to unit before servicing.
Disassembly Procedures
Coin Drop Acceptor
1. Disconnect power supply to unit.
Coin Sensor
1.  Disconnect power supply to unit.
2. Remove Coin Acceptor.
3. Remove screw securing Coin Sensor to the rear of the
Coin Drop Acceptor.
Door Assembly
1. Disconnect power supply to unit.
2. Open the door and remove the center screw of each
hinge secured to the inner flange of the front panel in
the door opening.
3. Grasp the door with both hands and lift the door in the
hinge area and draw the door assembly away from
the machine.  This will disengage the hinges from the
slots in the front shroud.
Slots
Hinge
5. Disconnect wiring harness for Coin Sensor.
6. Remove Coin Drop Acceptor
Coin Vault Switch
1.  Disconnect power supply to unit.
2.  Remove service access door and coin box.
3. Disconnect wires from the switch.
4.  Squeeze the two tabs on the switch and push the
switch through towards the front.
4.  Disconnect wires from the switch, and squeeze tabs
on switch to remove from bracket.
Service Door Switch
1.  Disconnect power supply to unit.
2.  Remove service access door.
3.  Remove the screw securing the switch mounting
bracket and lift the switch from inside the meter case.
2.  Unlock service access door.
3.  Loosen the two locking bolts from inside the meter
case.
4. Remove Control Panel.