Digital E and M Trunk Circuit Descriptor Assignment 
      
    
Number:  
  4 
Call Collision Handling:  
  AT&T 
AT&T Call Collision Handling:  
  Backoff 
Ignore Far End Disconnect:  
  No 
Release Acknowledge Timer:  
  80 
Address Signalling:  
  DTMF 
Disconnect Timer:  
  300 
Incoming Start Type:  
  Wink 
Dial Tone on Incoming Seize:  
  No 
Outpulse Delay Timer:  
  800 
Outgoing Start Type:  
  Wink 
Supervision Timer:  
  200 
Maximum Wink Timer:  
  400 
Minimum Wink Timer:  
  100 
Guard Timer:  
  500 
Fake Answer Supervision After Outpulsing:  
  No 
Ignore Answer Supervision:  
  No 
Release Supervisio n Expected:  
  Yes 
Audio Inhibit Until Answer Supervision:  
  Yes 
Far End Connection:  
  Main PBX 
Facility Type:  
  Combination
Minimum Flash Timer:  
  250 
Maximum Flash Timer:  
  200 
Drop Digit Rcvr for Outgoing Audio Before Ans Sup:   No 
Flash Timer:  
  300 
 
 
Trunk Service Assignment 
      
   
Trunk Service Number:  
 4 
Release Link Trunk:  
 No 
Class of Service:  
 4 
Class of Restriction:  
 1 
Baud Rate:  
 300 
Intercept Number:  
 1 
Non-dial In Trunks Answer Point - Day:  
  
Non-dial In Trunks Answer Point - Night 1:  
  
Non-dial In Trunks Answer Point - Night 2:  
  
Dial In Trunks Incoming Digit Modification - Absorb:  0 
Dial In Trunks Incoming Digit Modification - Insert:     
Trunk Label:  
 T1 Trunk