Cisco Systems 11500 Series ユーザーズマニュアル

ページ / 206
C-7
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-03
Appendix C      Troubleshooting
Troubleshooting the Boot Process
OffDM Verification of the Boot Configuration Record and Disk
During OffDM, the CSS checks the configuration record and initializes the disk. 
The following sections discuss:
Errors in the Boot Configuration Record
If the CSS detects any errors in the configuration record, a failed message appears 
along with information on the configuration parameter in question. The problems 
may include a misconfigured IP and subnet address, or there is no primary or 
secondary boot record. The CSS does not continue the boot process until the 
problem is resolved.
If a failed message occurs:
1.
Enter the OffDM menu and display your current configuration record. For 
detailed information on using OffDM, refer to the Cisco Content Services 
Switch Administration Guide
.
2.
Correct the misconfiguration. 
3.
Reboot the CSS. 
Note
If a MAC address error occurs, obtain technical assistance.