Uniden UBCT9 ユーザーズマニュアル

ページ / 68
4
Read the descriptions of the Plan 1~2 for details on which may apply for you.
PL(plan): If the last three digits of ALL the frequencies in use end in one of the following
three digits (125, 375, 625, or 875), use PL1(plan1).
PL (plan ): If the last three digits of ALL the frequencies in use end in one of the
following three digits (000, 250, 500, or 750) use Plan 2.
Of course, you will know the Control Channel frequency itself so that will help you 
determine the proper plan. If you try one plan and you receive errors (such as the scanner 
jumping to channels that are obviously not part of the system), you should try an alternate 
Plan.
Note:  •  You can assign a Fleet Map to TYPE 1 or Hybrid systems scanned in Control
 
  Channel Only mode by going into the Trunk Programming mode. You can also    
 
  program IDs, set a delay, and all the other parameters for systems scanned in this
 
  mode. You can then either search the system to find new IDs or you can program
 
  IDs into memory and then scan them.
 
•  The Control Channel Only feature is an extremely powerful tool. You can use it to
 
  determine if systems you are familiar with may have added new frequencies or    
 
  you can use it to discover new systems by simply finding active control channels   
 
  (using Search) and then programming them for Control Channel operation only.
 
  Remember that this feature only applies to Motorola 800 systems, that you do    
 
  have to set the proper system type (800 MHz of Type 1 or Type 2) and you do 
 
  have to program the Control Channel frequency into memory and identify the  
 
 
  frequency as trunked in the Trunk Programming mode.
Disconnect Tone Detect Option (End Code)
When this function is disabled, the radio looks for squelch before returning to the Control
Channel instead of waiting for the Disconnect Tone. Only in rare instances will you need to
adjust the default settings. The condition to return to Control Channels depends on whether
the signal is present or not.
1.   Press and hold TRUNK for 1.5 seconds and select the bank you want to change.
2.   Use the    or    key to select 
 (Motorola TYPE2 800MHz), 
 (Motorola  
  
 
Type2 VHF) or  
 (Motorola Type2 UHF), then press E.
3.   Use the    or    key to select 
, then press E.
4.   Use the    or    key to select 
 or 
, then press E
Note:  Set the SQL control so that you hear a hissing, and the scanner will remain on the
 
  voice channel (even when a disconnect tone is transmitted or there is no signal 
 
  at all).
UBCT9 OM   47
12/11/07   3:54:01 PM