GENERAL 
 
INTRODUCTION 
    This manual is prepared for the use of trained service technicians and should only be used by those 
who are properly qualified.  This manual is not intended to be all encompassing.  You should read, in 
it's entirety, the repair procedure you wish to perform to determine if you have the necessary tools, 
instruments and skills required to perform the procedure. Procedures for which you do not have the 
necessary tools, instruments and skills should not be attempted. 
 
 
Disconnect the electrical power and follow lockout / tagout procedures 
 
 
Certain procedures in this manual require electrical test or 
measurements while power is applied to the machine.  Exercise extreme caution at all 
times when attempting these procedures. Before testing, disconnect electrical power 
and follow lock/out tagout procedures, then attach test equipment and reapply power to 
test.   
 
     Procedures in this manual will apply to all RRG models unless specified.  No procedure in this 
manual will require the removal or raising of the griddle plate. Pictures and illustrations can be of any 
model unless the picture or illustration needs to be model specific.                 
 
 
 
 
INSTALLATION 
     Generally, installations are made by the dealer or contracted by the dealer or owner.  Detailed 
 
installation instructions are included in the Installation and Operation Manual that is sent with each unit. 
However, it should be noted that an improperly installed unit, especially an unlevel unit can lead to 
premature electrical component failures.  A unit that is higher in the front will cause the flue gases to 
vent improperly and gather in the front near the electrical components.  All RRG models  must be 
installed with an externally mounted regulator. 
 
OPERATION 
     Detailed operation instructions are included in the Installation & Operation Manual sent with each 
unit and are also available at  
WWW.VULCANHART.COM
 . 
 
 
 
 
 
 
 
 
 
CLEANING 
     Detailed cleaning procedures are included in the Installation & Operation manual sent with each 
unit. 
 
 
 
 
 
 
 
 
 
LUBRICATION 
     No lubrication is required on this equipment. 
 
 
 
 
 
 
 
 
 
SPECIFICATIONS 
     All RRG models operate on 120 volt, 60 hertz, single phase at 1.0 amps.  All models are equipped 
with electric solid state thermostats, automatic spark igniters and pilot safety circuit.  All models are 
equipped with 27,500 BTU/HR burners as standard equipment.  One burner is used for every 12 inches 
of griddle surface.  Natural gas models are to operate at 5.0" W.C. manifold pressure and LP models at 
10.0" W.C. manifold pressure with all burners on.