Vulcan Materials itw 36rrg ユーザーズマニュアル

ページ / 22
 
6
 - 
 
EXTERIOR PANELS 
 
CONTROL PANEL 
 
 
Disconnect the electrical 
power and follow lockout 
/ tagout procedures
 
The Control Panel holds the 
thermostats, indicator lights 
and power switch. 
 
REMOVAL 
1.  Remove the four screws 
securing the front of the 
control panel.  There are 
two screws at each end 
of the panel. 
2.  Remove the screws that 
secure the bottom of the 
control panel to the 
underside of the chassis. 
3.  Pull the control panel 
forward and lay face 
down directly in front of 
the unit while servicing. 
4.  Reverse the procedure to 
install. 
 
 
BULLNOSE 
 
 
Disconnect the electrical 
power and follow 
lockout / tagout 
procedures
 
The Bullnose acts as a front 
rail or shelf during griddle 
operation. 
REMOVAL 
1.  Remove the Control 
Panel. 
2.  The bullnose assembly is 
secured with several 
screws, one at each end 
of the bottom of the        
assembly and several 
more (depending on 
size) facing the griddle 
plate. 
3.  Reverse the procedure 
to install. 
 
 
 
BACK PANEL 
 
 
Disconnect the electrical power and 
follow lockout / tagout procedures
 
It will be necessary to remove the back panel when changing a 
burner, temperature probe or to remove excessive grease build up 
from the flue area. 
REMOVAL
 
1.  Disconnect gas supply at griddle. 
2.  Remove all screws from rear of griddle securing the back panel. 
3.  Reverse the procedure to install. 
 
IDENTIFICATION PLATE 
 
The identification plate contains the unit’s full model and serial 
number along with BTU rating and clearance information.  The 
identification plate is located on the right side panel towards the 
front of the unit. 
 
FLUE 
The flue is the outlet for gases left over from combustion and 
excess heat. The flue should never be blocked or covered. 
 
FLUE 
BACK PANEL 
  IDENTIFICATION PLATE  
BULLNOSE 
CONTROL PANEL