Disconnect the electrical power and follow lockout/tagout procedures 
 
THERMOSTAT REMOVAL 
1.  Remove the control panel 
2.  Remove the knob 
3.  Label and disconnect the wires 
4.  Remove the thermostat retaining nut on the knob shaft. 
5.  Reverse procedure to install while being careful to install the thermostat in the same orientation. 
 
 
TEMPERATURE PROBE 
 
 
The temperature probe is an embedded K 
type thermocouple assembly. 
 
 
 
 
Disconnect the 
electrical power and follow 
lockout/tagout procedures 
 
TEMPERATURE PROBE REMOVAL 
 
1. Remove the control panel 
2. Remove the back panel 
3. Label and disconnect the lead wires at 
    the temperature controller 
4. Unthread the probe retaining nut and  
    remove the probe from the back of the 
    unit. 
 
 
 
 
 
TEMPERATURE PROBE INSTALLATION 
 
1. Insert lead wires from back of heatshield 
    through to temperature controller. 
2. Apply a thin coating of high temp(500°  
    F min. rated),copper based heat transfer 
    and anti-seize compound to the probe tip  
    and retaining nut. 
3. Insert probe end into plate socket and 
    hand tighten probe retaining nut. 
4. Tighten the probe an additional ½ turn  
    only with a wrench.  Over tightening can 
    strip threads and damage probe tip. 
498432-A