Xerox 135 ユーザーズマニュアル
![Xerox](https://files.manualsbrain.com/attachments/0fe48d1f322308ffbf3238e7957ca0f7e8effce1/common/fit/150/50/5364c62dbb9b24e511428c3c1ad3cb3313d9aff7b5c826e56a00b9e021df/brand_logo.png)
Printer requirements and specifications
6-2
Installation Planning Guide
Outlet configurations
This section discusses specifications for printer outlets and the
required wall outlet configurations for the USA / Canada and
internationally.
required wall outlet configurations for the USA / Canada and
internationally.
NOTE: All power outlets must be dedicated to this equipment.
When determining the electrical connections for your printer,
make sure that:
When determining the electrical connections for your printer,
make sure that:
•
Each power cord has a separate circuit
•
The printer power cord configurations match your receptacle
•
Your electrical outlets are within the required specifications
50 Hz systems: Ensure that power connections are per local
codes/regulations.
codes/regulations.
60 Hz printer outlet voltages
The following table shows the voltages for the outlets on your
printer. All power outlets must have a dedicated circuit for each
system equipment piece. Make sure each power cord has a
separate circuit.
Table 6-2. Printer (60 Hz) voltage requirements at power
printer. All power outlets must have a dedicated circuit for each
system equipment piece. Make sure each power cord has a
separate circuit.
Table 6-2. Printer (60 Hz) voltage requirements at power
outlet
Service outlet
configuration
configuration
Measurement
of wiring
of wiring
Nominal
Range
4 Wire
Line 1 to neutral
120 V RMS
107-127 V RMS
4 Wire
Line 2 to neutral
120 V RMS
107-127 V RMS
4 Wire
Neutral to
ground
ground
0
0-10 V RMS
4 Wire
Line 1 to line 2
208 V RMS
182-220 V RMS
4 Wire
Line 1 to line 2
240 V RMS
210-254 V RMS