Xerox 135 ユーザーズマニュアル

ページ / 160
Printer requirements and specifications
6-4
 Installation Planning Guide
WYE (or Star)
configurations–
50 Hz
For the 50 Hz WYE configuration, measure the WYE or Star 
connection voltages at the power source. 
The following lists the 50 Hz WYE/Star printer outlet information 
for 380 and 400 volts.
Printer power
outlet/cord voltage
configurations–50
Hz
For 50 Hz systems outlet/power cord configurations, consult your 
local service representative to determine the type of plug and 
receptacle to use.
Table 6-3. Printer (50 Hz) WYE (Star) 415 voltage
Service outlet 
configuration
Measurement 
of wiring
Nominal
Range
5 Wire 415 V
Line 1 to line 2
415 V RMS
374-457 V RMS
5 Wire 415 V
Line 2 to line 3
415 V RMS
374-457 V RMS
5 Wire 415 V
Line 1 to Line 3
415 V RMS
374-457 V RMS
5 Wire 415 V
Line 1 to neutral
240 V RMS
216-264 V RMS
5 Wire 415 V
Line 2 to neutral
240 V RMS
216-264 V RMS
5 Wire 415 V
Line 3 to neutral
240 V RMS
216-264 V RMS
Table 6-4. Printer (50 Hz) WYE (Star) 380 and 400 voltage
Service outlet 
configuration
Measurement 
of wiring
Nominal
Range
5 Wire 380 V
Line 1 to line 2
380 V RMS
342-419 V RMS
5 Wire 380 V
Line 2 to line 3
380 V RMS
342-419 V RMS
5 Wire 380 V
Line 1 to Line 3
380 V RMS
342-419 V RMS
5 Wire 380 V
Line 1 to neutral
220 V RMS
198-242 V RMS
5 Wire 380 V
Line 2 to neutral
220 V RMS
198-242 V RMS
5 Wire 380 V
Line 3 to neutral
220 V RMS
198-242 V RMS
5 Wire 400 V
Line 1 to line 2
400 V RMS
358-438 V RMS
5 Wire 400 V
Line 2 to line 3
400 V RMS
358-438 V RMS
5 Wire 400 V
Line 1 to Line 3
400 V RMS
358-438 V RMS
5 Wire 400 V
Line 1 to neutral
230 V RMS
207-253 V RMS
5 Wire 400 V
Line 2 to neutral
230 V RMS
207-253 V RMS
5 Wire 400 V
Line 3 to neutral
230 V RMS
207-253 V RMS