If a BREAK symbol is received while the BDLC module is transmitting or receiving, the symbol invalid or out of range flag (in 
BDLC State Vector Register) is set. Further transmission/reception will be disabled until the J1850 bus returns to the passive state 
and a valid EOF symbol is detected on the J1850 bus. If the interrupt enable bit (IE in BDLC Control Register 1) is set, an interrupt 
request from the BDLC module is generated. Reading the BDLC State Vector Register register will clear this flag.
The BDLC module can transmit a BREAK symbol. And it can receive a BREAK symbol from the J1850 bus.
Bus Error Summary
The possible J1850 bus errors and the actions taken by the BDLC module are summarized in 
20.8.2
Mux Interface
The MUX Interface is responsible for bit encoding/decoding and digital noise filtering between the Protocol Handler and the Physical 
Interface. Refer to 
.
20.8.2.1
Mux Interface - Rx Digital Filter
The Receiver section of the BDLC module includes a digital low pass filter to remove narrow noise pulses from the incoming message. An 
outline of the digital filter is shown in 
.
Table 20-19. BDLC module J1850 Error Summary
Error Condition
BDLC Module Function
Transmission Error
BDLC module will immediately cease transmitting. Further 
transmission and reception will be disabled until a valid EOF symbol 
is detected. The symbol invalid or out of range flag will be set and 
interrupt generated if enabled. 
Cyclical Redundancy Check (CRC) 
Error
CRC error flag set and interrupt generated if enabled. 
Symbol Error
The symbol invalid or out of range flag will be set and interrupt 
generated if enabled. Transmission and reception will be disabled 
until a valid EOF symbol is detected.
Framing Error
The symbol invalid or out of range flag will be set and interrupt 
generated if enabled. Transmission and reception will be disabled 
until a valid EOF symbol is detected.
Bus short to V
DD
.
The BDLC module will not transmit until short is corrected and a 
valid EOF is detected. Depending upon when short occurs and is 
corrected, this error condition may set the symbol invalid or out of 
range, crc error, or loss of arbitration flags.
Bus short to GND.
Short will be seen as an idle bus by BDLC module. If a transmission 
attempt is made before short is corrected, the symbol invalid or out 
of range flag will be set and interrupt generated if enabled. Another 
transmission can be initiated as soon as short is corrected.
BREAK symbol reception
If doing so, the BDLC module will immediately cease transmitting. 
Symbol invalid or out of range flag set and interrupt generated if 
enabled.Transmission and reception will be disabled until a valid 
EOF symbol is detected.