DSC pc1616 ユーザーズマニュアル

ページ / 64
PowerSeries - PC1616/PC1832/PC1864
28
Programmable Output Options
01
Residential Burglary and Fire Bell Output
15
Remote Operation (DLS-3 Support)
02
For Future Use
16
For Future Use
03
Sensor Reset [*][7][2]
17
Away Armed Status
04
2 Wire Smoke Support (PGM 2 only)
18
Stay Armed Status
05
System Armed Status
19
Command Output #1 ([*][7][1])
06
Ready To Arm 
20
Command Output #2 ([*][7][2])
07
Keypad Buzzer Follow Mode
21
Command Output #3 ([*][7][3])
08
Courtesy Pulse
22
Command Output #4 ([*][7][4])
09
System Trouble Output (with Trouble options)
23
24 Hour Silent Input
10
System Event [Strobe (with Event options)]
24
24 Hour Audible Input
11
System Tamper (all sources: zones, keypad, modules)
25
Delayed Fire and Burglary Output
12
TLM and Alarm
29
Zone Follower Output
13
Kissoff Output
30
Partition Status Alarm Memory
14
Ground Start Pulse
[010] PGM3 to PGM10 Output Programming (Main Panel/PC5208) 
 Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default
Default
01
I_______I_______I
PGM 3 (main panel/PC5208)*
01
I_______I_______I
 
PGM 7 (PC5208)
01
I_______I_______I
PGM 4 (main panel/PC5208)*
01
I_______I_______I
PGM 8 (PC5208)
01
I_______I_______I
PGM 5 (PC5208)
01
I_______I_______I
PGM 9 (PC5208)
01
I_______I_______I
PGM 6 (PC5208)
01
I_______I_______I
PGM 10 (PC5208)
These two sections allow you to program both PGM3 and PGM4 on the main panel, and the first two PGM outputs on the PC5208. If you use 
both the main panel and the PC5208 outputs, PGM3 will work the same as the first PC5208 output, and PGM4 will work the same as the sec-
ond PC5208 output.
[011] PGM 11 to PGM 14 Output Programming (PC5204)
 
 Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default
Default
01
I_______I_______I
PGM 11
01
I_______I_______I
 PGM 
13
01
I_______I_______I
PGM 12
01
I_______I_______I
PGM 14
Other System Options
[012] Keypad Lockout Options 
 
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I_______I_______I_______I
Number of Invalid Codes Before Lockout (001-255 codes)
000
I_______I_______I_______I
Lockout Duration (001-255 minutes)
[006] Installer’s Code
[007] Master Code
[008] Maintenance Code
Default
Default
Default
5555   
I_______I_______I_______I_______I
1234
I_______I_______I_______I_______I
AAAA
I_______I_______I_______I_______I
[009] PGM1 and PGM2 Output Programming (Main Panel) 
 
Program PGM Option Attributes in sections [501] - [514]. Program PGM partitions in sections [551] - [564]
Default
Default
19
I_______I_______I
    PGM 1
10
I_______I_______I
    PGM 2
 Output types [03] and 
[20] cannot be used 
together on the same 
system.