Emergency Keys
Press the 
 (F),  
(A) or 
 (P) key for 2 seconds to generate a Fire, Auxiliary or
Panic alarm. The keypad sounder will beep indicating that the alarm input has been
accepted and transmission to the central station is underway.  Ask your alarm com-
pany if the emergency keys are available on your system
.
LED5511/LCD5511 Keypad
Press and Hold both keys simultaneously for 2 seconds to send the following mes-
sages:
Fire message
Auxiliary message
Panic Message
.
When Alarm Sounds
The system can generate 2 different alarm sounds:
Continuous Siren = Intrusion (Burglary Alarm)
Temporal / Pulsed Siren = Fire Alarm
Intrusion (Burglar) Alarm Continuous Siren
Fire Alarm Pulsed Siren
Follow your emergency evacuation plan immediately! 
If the fire alarm was accidental (i.e. burned toast, bathroom steam, etc.), enter your
Access Code to silence the alarm. Call your central station to avoid a dispatch. Ask
your alarm company if your system has been equipped with fire detection.
To reset the detectors, see the Sensor Reset section.
Function Keys
Keypads have 5 programmable one-touch function buttons located in a column down
the right-side of the keypad.  These buttons can also be activated by pressing and
holding number [1] through [5] respectively for 2 seconds.  The default for these
function buttons on the PK series keypads are as follows:
[1] Stay Arm
[2] Away Arm
[3] Chime Enable/Disable
[4] Fire/Reset - Command Output# 2
[5] Quick Exit
User Commands
Any system keypad can be used to program or perform any keypad command.  LED
keypads use status and zone indicator lights to represent alarm functions and status.
The LCD keypad provides a written description as well as status indicator lights rep-
resent alarm functions and status. This section provides basic information regarding
keypad commands.  Refer to the PC1616/1832/1864 Reference Manual for detailed
description of all keypad commands.
Away Arming
The Ready light must be ON to arm the system.  If the Ready light is OFF, ensure all
protected doors and windows are secure or bypassed.  To arm the system in the Away
mode, either press and hold the Away function button for 2 seconds or enter a valid
user code and leave the premises through a door programmed as Delay.  Upon arm-
ing, the Armed light will turn ON.  If a user code was used to arm the system and
Stay/Away zones are programmed, the Bypass light will turn ON and will turn OFF
when a door programmed as Delay is violated.  If the Audible Exit Delay option is
enabled, the keypad will beep once every second during the exit delay (and three
times a second during the last 10 seconds) to alert the user to leave.  
Stay Arming
The Ready light must be ON to arm the system.  If the Ready light is OFF ensure all
protected doors and windows are secure or bypassed.  To arm the system in the Stay
mode, either press and hold the Stay function button for 2 seconds or enter a valid
user code and stay within the premises (do NOT violate a door programmed as
Delay).  Upon arming, the Armed light and Bypass light will turn ON.  If the Stay
function button is used, the keypad will not beep during the exit delay to avoid
annoying the person staying in the premises.  If a user code was used, the keypad
will beep if the Audible Exit Delay option is enabled
.
Disarming
The user must enter through a door programmed as Delay.  Upon entering, the key-
pad will emit a steady tone (and emit a pulsing tone during the last 10 seconds of
entry delay) to alert the user to disarm the system.  Enter a valid user code to disarm
the system.  If an alarm occurred while the panel was armed, the Memory light and
the zones that went into alarm will be flashing (LED keypad) or the keypad will dis-
play ‘Alarm in Memory’ (LCD keypad). Press the [#] key to return the keypad to the
Ready state.
[
4
] Commands
[4][1] Bypass/Re-activate Stay/Away Zones
LED Keypad:
Press [4][1] to enter the bypass mode.  If the Code Required for Bypass option is
enabled, enter a valid user code.  The Bypass light will flash.  The keypad will turn
ON the corresponding zone light to indicate a zone is bypassed.  To bypass or unby-
pass a zone, enter the 2-digit zone number.  Once the correct zones are bypassed,
press [#] to exit.  The Bypass light will be ON if any zones are manually bypassed.
LCD Keypad:
Press [4][1] to enter the bypass mode.  If the Code Required for Bypass option is
enabled, enter a valid user code.  The keypad will display ‘Scroll to View Zones’.
The keypad will display the programmed zone labels for the zones and include the
letter ‘O’ in the bottom, right corner if the zone is violated or the letter ‘B’ if the
zone is bypassed.  Scroll to the appropriate zone and press the [4] key to change the
bypass status (or enter the 2-digit zone number).  Once the correct zones are
bypassed, press [#] to exit.
Additional Bypass Commands:
Bypass Recall:
Press [99]. Recalls the last group of zones bypassed
Clear Bypass:
Press [00]. Clears the bypass on all zones.
Save Bypass:
Press [95]. Saves zones that are manually bypassed.
Recall Save:
Press [91]. Recalls the bypassed zones that were saved.
Reactivate Stay/Away Zones:
Press [4][1] when the system is armed in the Stay mode to change the armed status
to Away mode.  The system will add the Stay/Away zones back into the system after
the exit delay time expires.
[4][2] Trouble Display
LCD Programmable-Message Keypad
Press [][2] to view a trouble condition. 
The trouble light will flash and the LCD will display the first trouble condition 
present.  
Use the arrow keys to scroll through all trouble conditions present.
 
LED Keypads, LCD Fixed Message Keypads
Press [][2] to view a trouble condition.  
The trouble light will flash.  
Refer to the Trouble Summary below to determine the trouble condition(s) present
.
[4][3] Alarm Memory Display
The Memory light will be ON if an alarm occurred during the last armed period.
Press [4][3]. The Memory light will flash and the keypad will display the zones that
went into alarm
.
[4][4] – Door Chime Enable/Disable
Press [4][4]. The keypad will emit 3 rapid beeps if the door chime feature is now
enabled and a steady 2-second tone if it is now disabled.  The same function can be
performed by pressing and holding the Chime function button for 2 seconds.
[4][5] – Program User Codes
The following table identifies available user codes:
LED Keypad:
Press [4][5] followed by the Master Code. The Program light will flash. The keypad
will turn ON the corresponding zone light to indicate a user code is programmed.
Enter the 2-digit user to be programmed.  The zone light will flash. Enter a new 4 or
Fire Keys can be disabled by the Installer.
If you are unsure of the source of the alarm approach with caution ! If the
alarm was accidental, enter your Access Code to silence the alarm. Call your
central station to avoid a dispatch.
Press the [#] key to reset the keypad if an error has been made entering user
codes or keypad commands.
SIA
For SIA FAR listed panels, The Stay Arming Exit Delay will be twice as long
as long as the Away Arming Exit Delay
When additional information is available for a specific trouble condition a
[
]
 will appear on the display. Press the 
[
]
 to view additional information.
Light
 [1]
 Service Required -Press [1] for more information
[1] 
Low Battery
[2] Bell Circuit
[3] General System Trouble
[4] General system Tamper
[5] Module Supervision
[6] RF Jam Detected
[7] PC5204 Low Battery
[8] PC5204 AC Failure
Light
 [2]
AC Trouble
Light
 [3]
Telephone Line Trouble
Light
 [4]
Failure to Communicate
Light
 [5]
Zone Fault -Press [5] for more information
Light
 [6]
Zone Tamper - Press [6] for more information
Light
 [7]
Wireless Device Low Battery - Press [7] for more information
Light
 [8]
Loss of Time or Date
To clear the Memory light, arm, then disarm the system.
Code
Type
Function
[01] – [32]
[33] – [34]
[40]
[41] – [42]
General User Codes
Duress Codes
Master Code
Supervisor Codes
arm, disarm
transmit duress reporting code
all functions
arm, disarm, program user codes