 For installations requiring a longer drain hose, have a 
qualifi ed technician install a longer drain hose (according to 
your model number) available from an authorized parts dis-
tributor. For drain systems in the fl oor, install a syphon break 
kit available from your local hardware store.
96”
(244cm)
max.
33”
(84cm)
min.
Drain system requirements
Drain capable of eliminating 17 gals (64.3 L) per minute.
A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
The standpipe height above the fl oor should be:
Minimum height:   33 in. (84 cm)
Maximum height:  96 in. (244 cm)
Water supply requirements
Hot and cold water faucets MUST be installed within 42 
inches (107 cm) of your washer’s water inlet. The faucets 
MUST be 3/4 inch (1.9 cm) with threading for laundry hose 
connection. Water pressure MUST be between 30 and 120 
psi. Pressure difference between hot and cold cannot be more 
than 10 psi. Your water department can advise you of your 
water pressure.
Clearance requirements
60 sq. in.
(387.1cm²)
3”
(7.6cm)
60 sq. in.
(387.1cm²)
3”
(7.6cm)
closet door
Installation in a Recess or Closet
If washer and dryer are installed in the same closet, door 
ventilation is required: A minimum of 120 square inches 
(774.2 cm²) of opening, equally divided at the top and 
bottom of the door, is required. Louvered openings should 
be located 3 inches (7.6 cm) from bottom and top of door. 
Air openings are required to be unobstructed when a door 
is installed. A louvered door with equivalent air openings for 
the full length of the door is acceptable.
 DO NOT INSTALL YOUR WASHER:
In an area exposed to dripping water or outside weather 
1. 
conditions. The ambient temperature should never be be-
low 60° F (15.6° C) to maximize detergent effectiveness
In an area (garage or garage-type building) where gaso-
2. 
line or other fl ammables (including automobiles) are kept 
or stored.
On carpet. Floor MUST be solid with a maximum slope 
3. 
of 1 inch (2.54 cm). To minimize vibration or movement, 
reinforcement of the fl oor may be necessary.
0”
(0 cm)
0”
(0 cm)
1”
(2.5 cm)
0”
(0 cm)
16”
(40.5 cm)
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES
REAR
TOP
FRONT
 Alcove
0” (0 cm) 0” (0 cm) 16” (40.5 cm)
n/a
 Under-
 Counter
n/a
n/a
n/a
n/a
 Closet
0” (0 cm) 0” (0 cm) 16” (40.5 cm)
1” (2.5 cm)