Removing Front Panel Of Heater
1.  Remove two screws near bottom corners 
of front panel.
2.  Lift straight up on grill guard until it stops. 
Grill guard will slide up about 1/4".
3.  Pull  bottom  of  front  panel  forward,  then 
down.
Figure 10 - Removing Front Panel Of 
Heater
Installing Bottom Mounting Screw
1.  Locate bottom mounting hole. This hole is 
near bottom on back panel of heater (see 
Figure 11).
2.  Mark screw location on wall.
3.  Remove heater from wall.
4.  If installing bottom mounting screw into hol-
low or solid wall, install wall anchor. Follow 
steps 1 through 5 under Attaching To Wall 
Anchor Method,
 page 9. If installing bottom 
mounting screw into wall stud, drill hole at 
marked location using 9/64" drill bit.
5.  Replace heater on wall.
6.  Insert bottom anchor screw through back 
panel into bottom anchor or drilled hole 
(see Figure 11).
7.  Tighten  screw  until  heater  is  firmly  se-
cured to wall. Do not over tighten.
 
Note: Do not replace front panel at this 
time.  Replace  front  panel  after  making 
gas connections and checking for leaks 
(see pages 10 through 13).
Figure 11 - Installing Bottom Mounting 
Screw
CONNECTING TO GAS SUPPLY
  WARNING:  This  appliance 
requires  a  3/8"  NPT  (National 
Pipe Thread) inlet connection to 
the pressure regulator.
 WARNING: A qualified service 
person must connect heater to gas 
supply. Follow all local codes.
  WARNING:  For  natural 
gas,  never  connect  heater  to 
private (non-utility) gas wells. 
This  gas  is  commonly  known 
as wellhead gas.
IMPORTANT: For natural gas, check gas line 
pressure before connecting heater to gas line. 
Gas  line  pressure  must  be  no  greater  than 
10.5" of water. If gas line pressure is higher, 
heater regulator damage could occur.
  CAUTION:  For  propane/LP 
gas,  never  connect  heater  di-
rectly to the propane/LP supply. 
This heater requires an external 
regulator  (not  supplied).  Install 
the external regulator between the 
heater and propane/LP supply.
For propane/LP gas, the installer must supply 
an external regulator. The external regulator 
will reduce incoming gas pressure. You must 
reduce incoming gas pressure to between 11" 
and 14" of water. If you do not reduce incom-
ing  gas  pressure,  heater  regulator  damage 
could  occur.  Install  external  regulator  with 
the  vent  pointing  down  as  shown  in  Figure 
12, page 11. Pointing the vent down protects 
it from freezing rain or sleet.
  CAUTION:  Use  only  new, 
black  iron  or  steel  pipe.  Inter-
nally-tinned copper tubing may 
be used in certain areas. Check 
your  local  codes.  Use  pipe  of 
large enough diameter to allow 
proper gas volume to heater. If 
pipe is too small, undue loss of 
volume will occur.