Namco Bandai Games 90500074 ユーザーズマニュアル

ページ / 131
Page 81
7-21
Replacing the Flat Target Motor
1.
Remove the upper rear maintenance door from the Target Cabinet.
2.
Remove the Flat Target Drive Cable 
(See section 7-20 page 80).
3.
Disconnect connectors (CN21) and (CN24).
4.
Loosen 2off double point screws (M5x6) and remove the pulley in the direction of
the arrow, as shown in the diagram below.
5.
Remove 4off flange socket screws (M4x10) and remove the Flat Target Motor.
Pulley
Double Point
(M5x6)
Connector
(CN21)
Flat Target Motor
Connector
(CN24)
Double Point
(M5x6)
Flange Socket Screw
(M4x10)
Flat Target Motor