U-Line Electrical / Plumbing Specfications
11
10 Prepare Power Supply
Electrical Specifications
WARNING
SHOCK HAZARD — Electrical Grounding Required. 
• Never remove the round grounding prong from the 
plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the 
unit.
IMPORTANT
IMPORTANT
Electrical installation must observe all state and local 
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a 
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A 
power supply (normal household current). An individual, properly 
grounded branch circuit or circuit breaker is recommended. GFCI 
(ground fault circuit interrupter) is usually not required for fixed 
location appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be sure to 
consult your local codes.
See below for recommended receptacle location
CLR2160 & CLRCO2175
CO29
24"
Acceptable
Location
Preferred
Location
for CLR2160
Receptacle
1"
7"
1-1/2"
7"
24"
4"
7"
24"
CO1175
CO29
CO2175FF
Receptacle Location
24"
Minimum
1-1/2"
7"
1-1/2"
7"
24"