 Server System SR1680MV Service Guide
33
Note: Before you remove or install the power supply, complete the following steps:
1. Make sure the server is not turned on or connected to the AC power. To power off 
the server, see 
.
2. Remove the motherboard cage module. To remove the cover, see 
.
3. Disconnect all necessary cable connections.
Removing an HDD Backplane
1. Loosen the two securing screws on the backplane.
2. Lift the backplane up from motherboard.
Figure 38. Remove the Screws and Lift the Backplane Up
Installing a 2.5-inch Pluggable SATA HDD Backplane
 steps to install the 2.5-inch pluggable SATA 
HDD backplane.
System Fans
Each I/O board cage module includes three system fans. The six system fans on the server 
system share the same removal and installation procedures. For your reference, this 
section provides the steps for replacing one system fan on the right I/O board cage module 
as an example.
The following figure shows the location of the system fan on the right I/O board cage 
module: