Vulcan Materials vulcan g60 ユーザーズマニュアル

ページ / 23
F35425 (October 2005)
Page 12 of 23
ENDURANCE SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
4.
Inside the oven remove the hex head bolts and
spacers attaching the motor grate to the motor
mounting plate and remove the motor grate.
5.
Remove the motor and rotor blower assembly
from inside the oven.
6.
Remove the fan from the motor.
7.
Remove motor from motor mounting plate.
8.
Reverse the procedure to install a new motor.
CONVECTION OVEN SOLENOID
WARNING:  DISCONNECT  THE
ELECTRICAL  POWER  TO  THE
MACHINE  AND  FOLLOW  LOCKOUT /
TAGOUT  PROCEDURES.
WARNING:  SHUT  OFF  THE  GAS  BEFORE
SERVICING  THE  UNIT.
WARNING:  ALL  GAS  JOINTS  DISTURBED
DURING  SERVICING  MUST  BE  CHECKED  FOR
LEAKS.  CHECK  WITH  A  SOAP  AND  WATER
SOLUTION  (BUBBLES).  DO  NOT  USE  AN
OPEN  FLAME.
1.
Disconnect gas supply to the range.
2.
Disconnect the solenoid electrical connectors.
3.
Disconnect gas supply lines from both sides of
the solenoid.
4.
Remove solenoid mounting screws and
solenoid.
5.
Reverse the procedure to install the
replacement solenoid.