Vulcan Materials vulcan g481 ユーザーズマニュアル

ページ / 23
F35425 (October 2005)
Page 7 of 23
6.
Slide the capillary tube out of the bracket and
straighten the tube so that it can be passed
through the hole in the oven sidewall.
7.
Carefully slide the capillary tube through the
hole in the oven sidewall.
8.
Disconnect the gas input to the control valve.
9.
Disconnect the pilot tubing.
10. Disconnect the control valve burner tubing.
11.
Remove the control valve assembly from the
oven.
12. Reverse the procedure to install a new control
valve assembly.
NOTE: During installation do not kink the new
capillary tube when feeding it through the hole in the
side of the oven cavity. Excess tubing can be loosely
wrapped.
ENDURANCE SERIES GAS RANGES - REMOVAL AND REPLACEMENT OF PARTS
Model 60, 260, and 481
The control valves are located behind the oven
manifold cover.
1.
Remove the oven manifold cover as outlined
under COVERS AND PANELS.
2.
Remove top burner grates and deflector,
if necessary, to access the control valve.
3.
Disconnect the pilot tubing from the control
valve.
4.
Remove two screws securing the control valve
to the manifold.