Lowrance lmf-400 ユーザーズマニュアル
46
5. Use the
UP
and
DOWN
keys to input the number you want to assign
to the tank and press
ENTER
. The Setting Tank Size window will
appear on the screen.
6. Use the
6. Use the
UP
and
DOWN
keys to input the size of the tank and press
ENTER
. You will be taken back to the Bus Devices list, where the tank
will be displayed as BlkWtr Tnk (1, 2 or 3).
To unconfigure Fluid Level:
1. Press
To unconfigure Fluid Level:
1. Press
MENU
, use the
UP
and
DOWN
keys to select
S
YSTEM
S
ETUP
and
press
ENTER
.
2. Highlight
B
US
D
EVICES
and press
ENTER
, which will open the Bus
Devices list.
3. Choose a configured Fluid Level from the Bus Devices list and press
3. Choose a configured Fluid Level from the Bus Devices list and press
ENTER
. The Fluid Level will appear with the following options: Level
Warning, Unconfigure, Reconfigure, Calibrate, Reset Cal and Reset
Values.
3. Highlight
3. Highlight
U
NCONFIGURE
and press
ENTER
, which will launch the
following message: Press Enter to Unconfig Device name.
4. Press
4. Press
ENTER
and you will be taken back to the Bus Devices list
where the fluid level you unconfigured will be displayed as UnCfg F
Level.
To reconfigure Fluid Level:
1. Press
To reconfigure Fluid Level:
1. Press
MENU
, use the
UP
and
DOWN
keys to select
S
YSTEM
S
ETUP
and
press
ENTER
.
2. Highlight
B
US
D
EVICES
and press
ENTER
. The Bus Devices list will
appear.
3. Select the Fluid Level you want to configure and press
3. Select the Fluid Level you want to configure and press
ENTER
.
4. The Fluid Level menu will appear with the following options: Level
Warning, Unconfigure, Reconfigure, Calibrate, Reset Cal and Reset
Values.
5. Choose
5. Choose
R
ECONFIGURE
and press
ENTER
. Use the
UP
and
DOWN
keys to
input the tank number you want to assign the fluid level and press
ENTER
. The Setting Tank Size window will appear on the screen.
6. Use the
UP
and
DOWN
keys to input the size of the tank and press
ENTER
. You will be taken back to the Bus Devices list, where the fluid
level will be displayed with its new configuration.
Level Warning
A Level Warning alerts you when the fluid level rises above or falls
Level Warning
A Level Warning alerts you when the fluid level rises above or falls
below a preset percentage of tank capacity. The Level Warning menu
has two options: Low Level and High Level. A low level warning is used
for fluid types like fuel, oil and freshwater, whereas a high level
warning is best suited for black water and Waste Water (Gray Water).