NOTE:
When following the steps below, run only ONE engine — the
engine connected to the fuel flow. That is the only way to accurately
calculate how much fuel passed through the fuel flow. Also, make
sure the fuel remaining source has been set to Eng/FFlow.
1. Fill up the tank you want to calibrate.
2. Press
2. Press
MENU
, use the
UP
and
DOWN
keys to select
S
YSTEM
S
ETUP
and
press
ENTER
.
3. Highlight
F
UEL
S
ETUP
and press
ENTER
.
3. Select
R
EFILL
T
ANK
and press
ENTER
. The Select Tank menu will open
with up to three options: Port, Center and Starboard.
4. Select the tank you refilled and press
4. Select the tank you refilled and press
ENTER
. The following message
will appear: Press Enter after refilling the fuel tank.
5. Press
5. Press
ENTER
and a calibration window will appear with two options:
Yes and No. Select
N
O
and press
ENTER
.
6. Take your boat out, but run only ONE engine — the engine
connected to the fuel flow. Burn at least 5 gallons of fuel, then fill up
the tank again, noting how much fuel was added to the tank. Check the
Fuel Manager page for the fuel used figure calculated by the LMF-400.
7. Compare the amount of fuel added when you filled up the tank with
7. Compare the amount of fuel added when you filled up the tank with
the LMF-400 Fuel Used figure. If the difference between these two
numbers is greater than 3 percent, you need to recalibrate the unit.
NOTE:
NOTE:
If the difference between the LMF-400 fuel used figure and the
amount of fuel you actually added to the tank is less than 3
percent, do not recalibrate the EP-10 Fuel Flow.
8. Fill up the fuel tank connected to the fuel flow you want to calibrate.
9. Press
9. Press
MENU
, use the
UP
and
DOWN
keys to select
S
YSTEM
S
ETUP
and
press
ENTER
.
10. Highlight
F
UEL
M
ANAGER
and press
ENTER
.
11. Select
R
EFILL
T
ANK
and press
ENTER
. The Select Tank menu will open
with three options: Port, Center and Starboard. Select the tank you
refilled and press
ENTER
.
12. The Recalibration menu will appear with two options: Yes and No.
Select
Y
ES
and press
ENTER
.
13. The Filled Quantity window will appear. Use the
UP
and
DOWN
keys to input the amount of fuel you added to the tank and press
ENTER
.
14. Repeat these steps for each fuel flow you want to calibrate.