Lowrance lmf-400 ユーザーズマニュアル

ページ / 72
54 
NOTE: 
It is a good idea to periodically check the calibration of a fuel flow.  
Reset Calibration 
The Reset Calibration command allows you to set fuel flow calibration 
back to default settings. 
To Reset Calibration for EP-10 Fuel Flow: 
1. Press 
MENU
, use the 
UP
 and 
DOWN
  keys  to  select 
S
YSTEM 
S
ETUP
 and 
press 
ENTER
2. Highlight 
B
US 
D
EVICES
 (Bus Devices) and press 
ENTER
. Highlight the 
fuel flow you want to reset and press 
ENTER
.  
3. Select 
R
ESET 
C
AL
 from the fuel flow menu and press 
ENTER
. The 
following message will appear: Press Enter to reset the Calibration.  
4. Press 
ENTER
 to set calibration back to default settings. To recalibrate 
the fuel flow, follow the steps in the previous segment regarding fuel 
flow calibration.  
Partial Fill 
You will use the Partial Fill option each time you add fuel without 
filling up the tank. 
To use Partial Fill: 
1. Scroll through the pages until the Fuel Manager page is on the 
screen, then press 
MENU
2. Use the 
UP
 and 
DOWN
 keys to highlight 
S
YSTEM 
S
ETUP 
and press 
ENTER
3. Select 
F
UEL 
S
ETUP
 and press 
ENTER
4. Choose 
P
ARTIAL 
F
ILL
 and press 
ENTER
. If you have more than one tank, 
the Select Tank menu will appear with up to three options (Port, 
Center and Starboard), depending on your engine-tank configuration. 
(If you have one tank, you will be taken directly to the Adding Fuel 
window.) 
5. Highlight the tank you partially filled and press 
ENTER
. That will 
open the Adding Fuel window.  
6. Use the 
UP
 and 
DOWN
 keys to enter the amount of fuel you added to 
the tank and press 
ENTER
. You will be taken back to the main display.  
Calibrating EP-15 Fluid Level 
The default calibration for the EP-15 Fluid Level is just as accurate as 
standard fluid level gauges. If, however, the tank has an irregular 
shape or greater accuracy is needed, calibration is recommended.  
The EP-15 Fluid Level has three calibration options: 2 point, 3 point 
and 5 point.