NOTE:
It is a good idea to periodically check the calibration of a fuel flow.
Reset Calibration
The Reset Calibration command allows you to set fuel flow calibration
The Reset Calibration command allows you to set fuel flow calibration
back to default settings.
To Reset Calibration for EP-10 Fuel Flow:
1. Press
To Reset Calibration for EP-10 Fuel Flow:
1. Press
MENU
, use the
UP
and
DOWN
keys to select
S
YSTEM
S
ETUP
and
press
ENTER
.
2. Highlight
B
US
D
EVICES
(Bus Devices) and press
ENTER
. Highlight the
fuel flow you want to reset and press
ENTER
.
3. Select
R
ESET
C
AL
from the fuel flow menu and press
ENTER
. The
following message will appear: Press Enter to reset the Calibration.
4. Press
4. Press
ENTER
to set calibration back to default settings. To recalibrate
the fuel flow, follow the steps in the previous segment regarding fuel
flow calibration.
Partial Fill
You will use the Partial Fill option each time you add fuel without
Partial Fill
You will use the Partial Fill option each time you add fuel without
filling up the tank.
To use Partial Fill:
1. Scroll through the pages until the Fuel Manager page is on the
To use Partial Fill:
1. Scroll through the pages until the Fuel Manager page is on the
screen, then press
MENU
.
2. Use the
UP
and
DOWN
keys to highlight
S
YSTEM
S
ETUP
and press
ENTER
.
3. Select
F
UEL
S
ETUP
and press
ENTER
.
4. Choose
P
ARTIAL
F
ILL
and press
ENTER
. If you have more than one tank,
the Select Tank menu will appear with up to three options (Port,
Center and Starboard), depending on your engine-tank configuration.
(If you have one tank, you will be taken directly to the Adding Fuel
window.)
5. Highlight the tank you partially filled and press
5. Highlight the tank you partially filled and press
ENTER
. That will
open the Adding Fuel window.
6. Use the
6. Use the
UP
and
DOWN
keys to enter the amount of fuel you added to
the tank and press
ENTER
. You will be taken back to the main display.
Calibrating EP-15 Fluid Level
The default calibration for the EP-15 Fluid Level is just as accurate as
The default calibration for the EP-15 Fluid Level is just as accurate as
standard fluid level gauges. If, however, the tank has an irregular
shape or greater accuracy is needed, calibration is recommended.
The EP-15 Fluid Level has three calibration options: 2 point, 3 point
The EP-15 Fluid Level has three calibration options: 2 point, 3 point
and 5 point.