Rabbit Tanaka Corporation Limited 72060 ユーザーズマニュアル
INSTRUCTIONS
TOOLS REQUIRED - PHILLIPS SCREW DRIVER TO CHANGE
UV-C BULB
UV-C BULB
Assembly
1
Connection
O-ring
Tube (3 sizes)
Fixer
Turbulence
Creator
O-ring
Tube (3 sizes)
Fixer
Switch
Water In
1
2
4
LED Lights
Power indicator
Lamp indicator
2
Power indicator
Lamp indicator
Status
On
On
Normal
On
Off
Lamp replacement
Off
Off
Transformer replacement
Switch
On
On
On
On
Supplied accessories
4. Medium Tube x 2
7. Turbulence Creator x 1
1. Transformer x 1
2. Fixer x 2
5. Large Tube x 2
8. Suction Cup x 1
3. Small Tube x 2
6. O-ring x 2
9. Hanger x 1
Water Out
Lamp Replacement
2
1
3
3
3
Cleaning of the quartz glass tube
A VITT TECHNOLOGY PRODUCT
5
Assembly - See diagram 1 . Follow the diagram to
assemble the unit.
assemble the unit.
Note that the suction cup is removable and that the spring
loaded plastic hanger is also removable. To remove the
suction cup pull the suction cup towards the empty space.
To install the suction cup insert and pull it into the original
space as shown in Assembly diagram 1 . To remove the
plastic spring loaded hanger twist the plastic hanger
counter clockwise and remove. To install the plastic spring
loaded hanger insert as shown on Assembly diagram 1 ,
and twist clockwise to lock in place.
loaded plastic hanger is also removable. To remove the
suction cup pull the suction cup towards the empty space.
To install the suction cup insert and pull it into the original
space as shown in Assembly diagram 1 . To remove the
plastic spring loaded hanger twist the plastic hanger
counter clockwise and remove. To install the plastic spring
loaded hanger insert as shown on Assembly diagram 1 ,
and twist clockwise to lock in place.
LED Lights - See diagram 2 The LED next to the on/ off
switch is the indicator light for the power supply. The LED
light on the top surface of the unit is the indicator light for
the bulb. Please note that if both indicator lights are out
the first thing to check is to confirm that the adaptor is in
an electrical supply socket that has power. The next step is
to check if the on/ off switch is in the on position. If after
insuring there is power coming to the unit and the LED for
the bulb is out while the power supply LED is on then the
bulb needs to be replaced. If both LED lights do not light
then replace the transformer.
switch is the indicator light for the power supply. The LED
light on the top surface of the unit is the indicator light for
the bulb. Please note that if both indicator lights are out
the first thing to check is to confirm that the adaptor is in
an electrical supply socket that has power. The next step is
to check if the on/ off switch is in the on position. If after
insuring there is power coming to the unit and the LED for
the bulb is out while the power supply LED is on then the
bulb needs to be replaced. If both LED lights do not light
then replace the transformer.
Lamp Replacement - Follow the instructions for removing
the four bolts as per the lamp replacement diagram.
When replacing the bulb, insert the ends of the bulb as
shown in the bulb installation diagram 3 and twist to
lock in place as shown.
the four bolts as per the lamp replacement diagram.
When replacing the bulb, insert the ends of the bulb as
shown in the bulb installation diagram 3 and twist to
lock in place as shown.
Connection - The unit may be hung from the side of
your aquarium as shown in the diagram 4 .Use supplied
suction cup to secure the unit in place at the other end of
the unit. You must check all connections to insure there is
no water leaking from the connections. Please note that
the direction of the flow of water must be from the end
with the turbulence creator to the other end that allows
the water to go back into the aquarium. Note water flow
indicator arrow on the ends of the blue tubes.
your aquarium as shown in the diagram 4 .Use supplied
suction cup to secure the unit in place at the other end of
the unit. You must check all connections to insure there is
no water leaking from the connections. Please note that
the direction of the flow of water must be from the end
with the turbulence creator to the other end that allows
the water to go back into the aquarium. Note water flow
indicator arrow on the ends of the blue tubes.
The unit can be used in the horizontal position as shown
in the diagram 5 . Please be sure that all air has been
removed from the unit and water lines to insure a
smooth flow of water. It is desirable that the intake of
water going from the aquarium and the output of clean
water going to the aquarium be as far apart as possible
to insure the maximum cleaning efficiency of the unit as
shown in the diagram 5 . The intake and output of water
for all types of installations should follow the illustrations
as closely as possible even when the unit is mounted by
hanging it on the side of the aquarium.
in the diagram 5 . Please be sure that all air has been
removed from the unit and water lines to insure a
smooth flow of water. It is desirable that the intake of
water going from the aquarium and the output of clean
water going to the aquarium be as far apart as possible
to insure the maximum cleaning efficiency of the unit as
shown in the diagram 5 . The intake and output of water
for all types of installations should follow the illustrations
as closely as possible even when the unit is mounted by
hanging it on the side of the aquarium.
Cleaning of the quartz glass tube - If you should ever
need to clean the quartz glass tube carefully disconnect the
water supply and carefully remove the plastic turbulence
creator using your fingers to grasp it or gently
withdrawing it with a pair of pliers before pushing a soft
bristle brush through the quartz glass tube back and forth
several times. This should need to be done only after a long
period of use. The unit is self cleaning by the patented
turbulence creator.
need to clean the quartz glass tube carefully disconnect the
water supply and carefully remove the plastic turbulence
creator using your fingers to grasp it or gently
withdrawing it with a pair of pliers before pushing a soft
bristle brush through the quartz glass tube back and forth
several times. This should need to be done only after a long
period of use. The unit is self cleaning by the patented
turbulence creator.