u-blox AG NINAW10 ユーザーズマニュアル

ページ / 44
NINA-W10 series - Data Sheet 
 UBX-17065507 - R01
 
 
Electrical specifications 
 
 
Page 17 of 44 
4  Electrical specifications 
 
Stressing  the  device  above  one  or  more  of  the  ratings  listed  in  the  Absolute  maximum  rating 
section  may  cause  permanent  damage.  These  are  stress  ratings  only.  Operating  the  module  at 
these or at any conditions other than those specified in the Operating conditions section of this 
document  should  be  avoided.  Exposure  to  absolute  maximum  rating  conditions  for  extended 
periods may affect device reliability. 
 
Operating  condition  ranges  define  those  limits  within  which  the  functionality  of  the  device  is 
guaranteed.  Where  application  information  is  given,  it  is  advisory  only  and  does  not  form  part  of  the 
specification. 
4.1  Absolute maximum ratings 
Symbol 
Description 
Condition 
Min 
Max 
Unit 
VCC/ 
VCC_IO 
Module supply voltage 
Input DC voltage at VCC and VCC_IO pins 
-0.3 
3.9 
I
VCC
 
MAX
 +  
I
VCC_IO
 
MAX
 
Absolute maximum power 
consumption 
 
 
500 
mA 
DPV 
Digital pin voltage 
Input DC voltage at any digital I/O pin 
-0.3 
3.9 
P_ANT 
Maximum power at receiver 
Input RF power at antenna pin 
 
+10 
dBm 
Tstr 
Storage temperature 
 
-40 
+85 
ºC 
Table 7: Absolute maximum ratings 
 
The  product  is  not  protected  against  overvoltage  or  reversed  voltages.  If  necessary,  voltage 
spikes exceeding the power supply voltage specification, given in table above, must be limited to 
values within the specified boundaries by using appropriate protection devices. 
4.1.1  Maximum ESD ratings 
Parameter 
Min. 
Typical  Max. 
Unit 
Remarks 
ESD sensitivity 
 
 
500 
Human body model according to JEDEC JS001 
 
 
250 
Charged device model according to JESD22-C101 
Table 8: Maximum ESD ratings 
 
NINA-W10 series modules are Electrostatic Sensitive Devices and require special precautions while 
handling. See section 8.4 
for ESD handling instructions.