Trane US Inc. CONT8241 ユーザーズマニュアル

ページ / 38
 
824 Programmable Comfort Control
18-HD72D1-1  
page 21
5.2  Guided System Configuration Tool
The Guided System Configuration Tool walks you step by step through the configuration process. The Tool appears when 
the 824 is powered on for the first time and when the Restore Factory Defaults function is invoked. 
After each step, a progress screen will show what steps have been completed and which ones are still pending. 
MENU ITEM
DESCRIPTION
Time and Date [User]
Set the current time, date and time zone. 
Installer Setup
From the Installer Setup screen, select a preset that matches the system’s configuration (i.e. Single Stage 
AC, Standard Heat Pump, Multi-Stage Heat Pump, Standard Dual fuel, etc.). Based on this selection, the 
824 automatically sets a number of parameters and options. Subsequent screens provide details of the 
settings and allow for manual editing of each parameter.
Service Reminders
Set the mode and frequency of Air Filter, ERV Service and System Maintenance Reminders. When a 
reminder is triggered, an alert will appear on the 824 Home Screen notifying the homeowner to contact 
their dealer for service.
Schedule [User]
Guided Scheduling [User]
Screen  [User]
Wireless Network [User]
Dealer Code
Registration [User]
Weather [User]
[User] indicates menu items that are included in the User Setup Tool.
5.3  Installer Setup
5.3.1 Group 1 Standard Settings
MENU ITEM
OPTIONS [DEFAULT]
DESCRIPTION
Outdoor Unit Type
None, [Cooling Only], HP
Select the type of outdoor unit installed
Outdoor Unit Stages
[Single Stage], Two Stage
Select the number of outdoor unit stages
Compressor Type
Single Compressor Two Stage, 
[Two Compressor Two Stage]
Select the compressor type for multi-stage outdoor 
units
Indoor Unit Type
[Gas/Oil], Electric, Hydronic
Select the type of indoor unit installed
Indoor Heat Stages
[Single Stage], Two Stage, Thee Stage
Select the number of indoor heat stages
Indoor Blower Type
Variable, [Non - Variable]
Select the indoor blower type (Constant Torque motors 
are considered non-variable speed)
Reversing Valve