4. Click Add
The configurable fields of the Power Control tabbed page 
are described in the following table: 
Table 23: Cell Power Control Fields 
Field Name 
Description 
Values 
LAC 
Indicates the location area code of the cell. 
1 to 65533, 
65535 
Cell ID 
Refers to the cell identifier. 
0 to 65535 
Enable MS 
PWR CTRL 
Controls, if UL power control (that is control of 
MS Tx power) is activated/deactivated in a cell. 
true/false 
Enable BS 
PWR CTRL 
Controls if DL power control (that is control of 
BS Tx power) is activated/deactivated in a cell. 
true/false 
Min Rx Lev UL 
Indicates the lower threshold for the Rx power 
level measured on uplink. If the BTS/TRX 
reports a lower level, the uplink power is 
increased. 
•  0: measured signal level  < -110 
dBm 
•  1: -110 dBm < measured signal 
level < -109 dBm 
•  2: -109 dBm < measured signal 
level < -108 dBm 
• ... 
•  62: -49 dBm < measured signal 
level < -48 dBm 
•  63: -48 dBm < measured signal 
0 to 63