Field Name 
Description 
Values 
level 
Consistency Conditions
Min Rx Lev UL < Max Rx Lev UL 
Max Rx Lev UL  - Min Rx Lev UL > 
incrStepSizeP 
Max Rx Lev UL  - Min Rx Lev UL > 
safetyMarginP 
Min Rx Lev UL HO < Min Rx Lev UL 
Max Rx Lev UL  Indicates the upper threshold for the Rx power 
level measured on uplink. If the BTS/TRX 
reports a higher level, the uplink power is 
reduced. 
•  0: measured signal level < -110 
dBm 
•  1: -110 dBm < measured signal 
level < -109 dBm 
•  2: -109 dBm < measured signal 
level < -108 dBm 
• ... 
•  62: -49 dBm < measured signal 
level < -48 dBm 
•  63:  -48 dBm < measured signal 
level 
Consistency Conditions
Min Rx Lev UL < Max Rx Lev UL 
Max Rx Lev UL  - Min Rx Lev UL > 
0 to 63