4RF Limited SRN0400025A ユーザーズマニュアル

ページ / 233
 
Alarm Types and Sources  |  217 
 
Aprisa SR User Manual 
 
Receiver Alarms 
Event ID  
Event Display 
Text  
Default 
Severity  
Configuration 
Type  
Function 
7  
RSSI Threshold  
warning(4)  
Threshold Type   Alarm to indicate that the receiver RSSI 
reading taken on the last packet received 
is outside defined limits. 
8  
RX Synthesizer 
Not Locked  
critical(1)  
Not 
Configurable 
Alarm to indicate that the receiver 
Synthesizer is not locked on the RF 
received signal. 
9  
RX CRC Errors  
warning(4)  
Error Ratio 
Type  
Alarm to indicate that the data received 
on the RF path contains errors at a higher 
rate than the defined error rate threshold. 
 
Radio Interface Path Alarms 
Event ID  
Event Display 
Text  
Default 
Severity  
Configuration 
Type  
Function  
34  
RF No Receive 
Data  
warning(4)  
Sample 
Duration Type  
Alarm to indicate that there is no data 
received on the RF path in the defined 
duration period. 
 
Customer Equipment Interface Path Alarms 
Event ID  
Event Display 
Text  
Default 
Severity  
Configuration 
Type  
Function 
10  
Port 1 Eth No 
Receive Data  
warning(4)  
Sample 
Duration Type  
Alarm to indicate that Ethernet port 1 has 
no received input signal in the defined 
duration period. 
11  
Port 1 Eth Data 
Receive Errors  
warning(4)  
Error Ratio 
Type  
Alarm to indicate that Ethernet port 1 
received input signal contains errors at a 
higher rate than the defined error rate 
threshold. 
12  
Port 1 Eth Data 
Transmit Errors  
warning(4)  
Error Ratio 
Type  
Alarm to indicate that Ethernet port 1 
transmitted output signal contains errors 
at a higher rate than the defined error 
rate threshold. 
35  
Port 2 Eth No 
Receive Data  
warning(4)  
Sample 
Duration Type  
Alarm to indicate that Ethernet port 2 has 
no received input signal in the defined 
duration period. 
36  
Port 2 Eth Data 
Receive Errors  
warning(4)  
Error Ratio 
Type  
Alarm to indicate that Ethernet port 2 
received input signal contains errors at a 
higher rate than the defined error rate 
threshold. 
37  
Port 2 Eth Data 
Transmit Errors  
warning(4)  
Error Ratio 
Type  
Alarm to indicate that Ethernet port 2 
transmitted output signal contains errors 
at a higher rate than the defined error 
rate threshold. 
13  
Serial Data No 
Receive Data  
warning(4)  
Sample 
Duration Type  
Alarm to indicate that the RS-232 port has 
no received input signal in the defined 
duration period. 
14  
Serial Data 
Receive Errors  
warning(4)  
Error Ratio 
Type  
Alarm to indicate that the RS-232 port 
received input signal contains errors at a 
higher rate than the defined error rate 
threshold.