218  |  Alarm Types and Sources 
 
 
Aprisa SR User Manual 
 
Component Failure Alarms 
Event ID  
Event Display 
Text  
Default 
Severity  
Configuration 
Type  
Function 
16  
Component 
Failure  
major(2)  
Not 
Configurable 
Alarm to indicate that a hardware 
component has failed. 
 
Diagnostic Alarms 
Event ID  
Event Display 
Text  
Default 
Severity  
Configuration 
Type  
Function 
17  
Protection Sw 
Manual Lock  
warning(4)  
Not 
Configurable 
Alarm to indicate that the Protection 
Switch Software Manual Lock has been 
activated. 
18  
Protection Hw 
Manual Lock  
warning(4)  
Not 
Configurable 
Alarm to indicate that the Protection 
Switch Hardware Manual Lock has been 
activated. 
 
Software Alarms 
Event ID  
Event Display 
Text  
Default 
Severity  
Configuration 
Type  
Function  
20  
Calibration 
Failure  
major(2)  
Not 
Configurable 
Alarm to indicate that the RF calibration 
has failed. 
21  
Configuration 
Not Supported  
major(2)  
Not 
Configurable 
Alarm to indicate that a configuration has 
entered that is invalid. 
32  
Network 
Configuration 
Warning  
warning(4)  
Not 
Configurable 
Alarm to indicate a network configuration 
problem e.g. duplicate IP address. 
39  
Software 
Restart 
Required  
warning(4)  
Not 
Configurable 
Alarm to indicate that a configuration has 
changed that requires a software reboot. 
 
Protection Alarms 
Event ID  
Event Display 
Text  
Default 
Severity  
Configuration 
Type  
Function 
23  
Protection Peer 
Comms Lost  
major(2)  
Not 
Configurable 
Alarm to indicate that the standby radio 
has lost communication with the active 
radio. 
54  
Protection 
Hardware 
Failure  
major(2)  
Not 
Configurable 
Alarm to indicate that there is a failure in 
the protection switch hardware.