Product Options  |  29 
 
Aprisa SR User Manual 
 
Configuration Management  
The  Primary  and  Secondary  radios  are  managed  with  the  embedded  web-based  management  tool, 
SuperVisor  (see  ‘Managing  the  Radio’  on  page  59)  by  using  either  the  Primary or  Secondary  IP  address. 
Configuration changes in one of the radios will automatically be reflected in the partner radio. 
To ensure all remote stations are registered to the correct (active) base station, changes to the Network 
Table  are  automatically  synchronized  from the  active  radio  to the  standby  radio.  The  Network  Table  is 
only visible on the active radio. This synchronization does not occur if the Hardware Manual Lock is active. 
 
Switch Over 
The switch over to the standby radio can be initiated automatically, on fault detection, or manually via 
the Hardware Manual Lock switch on the Protection Switch or the Software Manual Lock from SuperVisor. 
Additionally,  it  is  possible  to  switch  over  the  radios  remotely  without  visiting  the  station  site,  via  the 
remote control connector on the front of the Protection Switch. 
On detection of an alarm fault the switch over time is less than 0.5 seconds. Some alarms may take up to 
5 seconds to be detected. 
The Protection Switch has a switch guard mechanism to prevent protection switch oscillation. If a switch-
over has occurred, subsequent switch-over triggers will be blocked if the guard time has not elapsed. 
The  guard  time  starts  at  20  seconds  and  doubles  each  switch-over  to  a  maximum  of  320  seconds  and 
halves after a period of two times the last guard time with no protection switch-overs. 
 
Switching Criteria 
The  Protected  Station  will  switch  over  operation  from  the  active  to  the  standby  radio  if  any  of  the 
configurable alarm events occur, or if there is a loss of the ‘keep alive’ signal from the active radio. 
It is possible to configure the alarm events which will trigger the switch over. It is also possible to prevent 
an alarm event triggering a switch over through the configuration of blocking criteria. 
Any of the following alarm events can be set to trigger or prevent switching from the active radio to the 
standby radio (see ‘Events > Events Setup’ on page 137)
 
  PA current 
  Tx AGC 
  Tx reverse power 
  Thermal shutdown 
  Temperature threshold 
  Thermal shutdown 
  RSSI Threshold 
  RX Synthesizer Not Locked 
  Rx CRC errors 
  RF no receive data 
  Ethernet port 1 – no receive data 
  Ethernet port 2 – no receive data 
  Ethernet port 1 - data receive errors 
  Ethernet port 2 – data receive errors 
  Ethernet port 1 – data transmit errors 
  Ethernet port 2 - data transmit errors 
  Serial port – no receive data 
  Serial port – data receive errors 
  Component failure 
  Calibration failure 
  Configuration not supported 
  Protection Hardware Failure 
 
It will not attempt to switch over to a standby radio which has power failure. 
It will also not switch over to a standby radio with an active alarm event which has been configured as a 
‘blocking criteria’.