4RF Limited SRN0400025A ユーザーズマニュアル

ページ / 233
30  |  Product Options 
 
 
Aprisa SR User Manual 
 
Switch  over  will  be  initiated  once  either  of  these  conditions  is  rectified,  i.e.  power  is  restored  or  the 
alarm is cleared. 
 
Hardware Manual Lock 
The  Hardware  Manual  Lock  switch on  the  Protection  Switch  provides  a  manual  override  of  the  active  / 
standby radio. 
When  this  lock  is  activated,  the  selected  radio  (A  or  B)  becomes  the  active  radio  regardless  of  the 
Software Manual Lock and the current switching or block criteria. 
When  the  lock  is  deactivated  (set  to  the  Auto  position),  the  protection  will  become  automatic  and 
switching will be governed by normal switching and blocking criteria. 
 
 
 
The state of the switch is indicated by the three LEDs on the Protection Switch: 
 
A LED 
B LED 
Locked LED 
State 
Green 
Off 
Off 
Auto - Radio A is active 
Off 
Green 
Off 
Auto - Radio B is active 
Green 
Off 
Orange 
Manual Lock to radio A 
Off 
Green 
Orange 
Manual Lock to radio B 
 
The Protection Switch also has a Software Manual Lock (see ‘Protected Station: Maintenance > Protection’ 
on page 179). The Hardware Manual Lock takes precedence over Software Manual Lock if both diagnostic 
functions are activated i.e. if the Software Manual Lock is set to ‘Primary’ and the Hardware Manual Lock 
set to ‘Secondary’, the system will set the Secondary radio to Active. 
When a Hardware Manual Lock is deactivated (set to the Auto position), the Software Manual Lock is re-
evaluated and locks set appropriately. 
 
Remote Control 
The switch over to the standby radio can be initiated via the Remote Control connector on the front of the 
Protection  Switch.  This  control  will only  operate if the Hardware Manual Lock switch is set to the  Auto 
position. 
 
 
 
The inputs are logic inputs with 4700 Ω pullup to +3.3 VDC. They require a pull down to ground to activate 
the control.  The  ground  potential is  available on the  connector  (see  ‘Protection  Switch  Remote Control 
Connections’
 on page 215).